High-Flow or Standard Oxygen in Acute Hypoxemic Respiratory Failure.
Summary
High-Flow or Standard Oxygen in Acute Hypoxemic Respiratory Failure. Original Article Abstract Background Data are needed on the effect of oxygen delivered through a high-flow nasal cannula, as compared with standard oxygen therapy, on intubation and mortality in patients with acute hypoxemic respiratory failure. Methods In this multicenter, open-label trial, we randomly assigned patients who had acute hypoxemic respiratory failure to receive high-flow-oxygen or standard-oxygen therapy. A
Content
# High-Flow or Standard Oxygen in Acute Hypoxemic Respiratory Failure.
*Original Article*
# Abstract
## Background
Data are needed on the effect of oxygen delivered through a
high-flow nasal cannula, as compared with standard oxygen therapy, on intubation
and mortality in patients with acute hypoxemic respiratory failure.
## Methods
In this multicenter, open-label trial, we randomly assigned patients
who had acute hypoxemic respiratory failure to receive high-flow-oxygen or
standard-oxygen therapy. All the patients had a ratio of the partial pressure of
arterial oxygen to the fraction of inspired oxygen of 200 or less, a respiratory
rate of more than 25 breaths per minute, and pulmonary infiltrate on chest
imaging. The primary outcome was death by day 28.
## Results
A total of 1116 patients underwent randomization. Of these patients,
1110 (556 in the high-flow-oxygen group and 554 in the standard-oxygen group)
were included in the analysis. Mortality at day 28 was 14.6% (in 81 of 556
patients) in the high-flow-oxygen group and 14.6% (in 81 of 554 patients) in the
standard-oxygen group (difference, -0.05 percentage points; 95% confidence
interval [CI], -4.21 to 4.10; Pā=ā0.98). The incidence of intubation by day 28
was 42.4% (in 236 of 556 patients) in the high-flow-oxygen group and 48.4% (in
268 of 554 patients) in the standard-oxygen group (difference, -5.93 percentage
points; 95% CI, -11.78 to -0.08). Serious adverse events (cardiac arrest or
pneumothorax) occurred during spontaneous breathing in 13 patients (2.3%) in the
high-flow-oxygen group and in 6 patients (1.1%) in the standard-oxygen group.
## Conclusions
Among patients with acute hypoxemic respiratory failure, the use of
oxygen delivered through a high-flow nasal cannula did not significantly reduce
mortality at day 28. (Funded by the French Ministry of Health and Fisher and
Paykel Healthcare; SOHO ClinicalTrials.gov number, NCT04468126.).
---